The Cockcroft Gault formula is often used to calculate the glomerular filtration rate (GFR) from plasma creatinine results. In Sweden this calculation is not usually done in the laboratory, but locally in the wards. These manual calculations could cause erroneous results. In several studies plasma cystatin C has been shown to be superior to plasma creatinine for estimation of GFR. One limitation of using cystatin C as a GFR marker is that there is no conversion formula transforming cystatin C expressed as mg/L to GFR expressed as mL/min. In this study plasma creatinine and cystatin C were compared with iohexol clearance. A stronger correlation (p