The purpose of this study was to assess the agreement, mean difference, and the detection and control rates of hypertension, between home and clinic blood pressure (BP) measurement in the Finnish population. Variation in home BP during the measurements was also examined.
We studied a representative sample of the adult population (2051 45-74-year-old individuals) in Finland. Subjects included in the study underwent a clinical interview and measurement of clinic and home BP. Thresholds for elevated clinic and home BP were 140/90 and 135/85 mmHg.
The mean difference between home and clinic BP, which increased with BP, was 7.7/3.4 mmHg. Overall agreement in diagnosis was only 75.2% (kappa coefficient 0.50). As compared with home BP, clinic BP overestimated the prevalence of hypertension (48.8 versus 42.5%, P